AC Drives (VFD)
Challenges, solutions and FAQ's related to AC Drives (VFD).
FMX TD200 Series
- AN-GEN-004 - How to determine your motor’s FLA
- AN-GEN-006 - How to calculate the derated output current for a three-phase AC drive
- AN-TD2-001 - How to setup PID control for TD200 series AC drives.
- AN-TD2-002 - Cross reference charts for FM50 series to TD200 series AC drives.
- AN-TD2-003 - How to set the Frequency Source for TD200 series AC drives.
- AN-TD2-004 - How to set the Run Command Source for TD200 series AC drives
- AN-TD2-005 - How to setup a digital input on the TD200 series AC drive as an Emergency Stop
- AN-TD2-006 - How to setup the TD200 to use Jog controls
- AN-TD2-007 - How to setup the Analog Output on TD200 series AC drives
- AN-TD2-008 - How to check the Motor Rotation Direction for Accuracy
- AN-TD2-010 - How to use a panel meter and potentiometer to provide external speed display and control with the TD200
- AN-TD2-011 - Establishing a connection between the Tough Drive and TD-Link software
- AN-TD2-015 - TD200 Drive Error Codes
- AN-TD2-016 - Tough Drive STP0 Display on Start
FMX TD400 Series
- AN-GEN-004 - How to determine your motor’s FLA
- AN-GEN-006 - How to calculate the derated output current for a three-phase AC drive
- AN-TD4-002 - How to setup PID control for TD400 series AC drives
- AN-TD4-003 - How to setup PID control for TD400 series AC drives using optional remote LCD keypad
- AN-TD4-004 - Cross reference charts for CV7300 series to TD400 series AC Drives
- AN-TD4-005 - How to set the Frequency Source for TD400 series AC drives
- AN-TD4-006 - How to set the Run Command Source for TD400 series AC drives
- AN-TD4-007 - How to setup a digital input on the TD400 series AC drive as an Emergency Stop
- AN-TD4-008 - How to setup the TD400 to use Jog controls
- AN-TD4-009 - How to setup the Analog Output on TD400 series AC drives
- AN-TD4-010 - How to check the Motor Rotation Direction for Accuracy
- AN-TD4-011 - Differences Between Constant and Variable Torque
- AN-TD4-012 - How to wire externally powered devices to the TD400 input terminals
- AN-TD4-013 - How to use a panel meter and potentiometer to provide external speed display and control
- AN-TD4-014 - Downloading and installing the TD-Link software
- AN-TD4-015 - Using the keypad to enter the VFD parameters
- AN-TD4-016 - Connecting the Tough Drive to TD-Link Software
- AN-TD4-017 - Connecting the Tough Drive to an iView HMI
- AN-TD4-018 - Tough Drive Configuration with TD-Link
- AN-TD4-019 - Programming the TD400’s internal PLC for motor control.
- AN-TD4-020 - TD400 PLC Timer Instruction
- AN-TD4-021 - TD400 PLC Counter Instruction
- AN-TD4-022 - TD400 PLC Comparison Instruction
- AN-TD4-023 - TD400 PLC Math Instructions
- AN-TD4-024 - Setting Up BACnet on the TD400
- AN-TD4-029 - How to use the LCD keypad to copy parameter settings from one TD400 drive to another.
- AN-TD4-031 - TD400 Drive Error Codes
- AN-TD4-032 - Tough Drive STP0 Display on Start
TECO FM50 Series
- AN-GEN-004 - How to determine your motor’s FLA
- AN-GEN-006 - How to calculate the derated output current for a three-phase AC drive
- AN-VFD-007 - How to wire and program a FM50 VFD for 3-Wire Control.
- AN-VFD-008 - How to wire and program a FM50 VFD for 2-Wire Control Mode
- AN-VFD-009 - FM50 Remote Potentiometer Frequency Control
TECO CV7300 Series
- AN-GEN-004 - How to determine your motor’s FLA
- AN-GEN-006 - How to calculate the derated output current for a three-phase AC drive
- AN-TD4-004 - Cross reference charts for CV7300 series to TD400 series AC Drives
- AN-VFD-001 - MA7200 Cross Reference Chart
- AN-VFD-002 - Single Phase Input for CV7300
- AN-VFD-003 - 3-Wire Control Set-up and Wiring CV7300
- AN-VFD-004 - 2-Wire Control Setup and Wiring for CV7300
- AN-VFD-005 - Remote Potentiometer Frequency Control for CV7300
- AN-VFD-010 - MA7200-CV7300 Parameter Conversion